    Chlorine

    Chlorine sensor for water quality measurement

    The basic concept of measurement with the AquaSens chlorine measuring cell consists of a 2-electrode cell, a working (Pt) and a counter-electrode (Cu). This continuous potentiostatic measurement does not require a diffusion membrane, which significantly increases the response sensitivity. The special AquaSens flow fitting ensures a constant sample water flow and guarantees easy cleaning of the copper electrode without mechanical devices. The AquaSens chlorine measuring cell also copes well with very heavily polluted water. Together, the measuring cell and flow fitting form a compact measuring device.

    Chlorine measurement sensitivity

    Technical Specifications

    Measurement methodPotentiostatic amperometry
    Measuring cellCopper-platinum
    Measuring range0…20 mg/l
    Sensitivityless than 1 ppb
    Measurement signallinear: 0.01…10 mg/l, 0.5…500 microamps
    Response time30s (T90– value)
    Cleaningcontinuously with quartz sand
    Sample water flowapprox. 32 l/h
    link
    Overview
    Water Sensors
    link
    AquaSens Flow Fitting
    houses chlorine measuring cell
    SWISS MADE
    Swiss Quality Product
    artikelnummer
    MEAS-MZ-18
    MEAS-MZE-18
    MEAS-MZE-88
    Article codes