CO
Gas | Carbon Monoxide |
Formula | CO |
CAS number | 630-08-0 |
Max. workplace concentration | 30 ppm |
Relative density | 0.97 |
Appearance | Colorless Odorless |
Hazards | Toxic Dizziness |
The ME1250 gas sensor is a remote measuring unit for monitoring the gas concentration of carbon monoxide. This toxic gas is mainly found in the exhaust of petrol engines. The sensor is used to control ventilation and to alert for evacuation.
The microprocessor-controlled electronics of the sensor, adapted to the specific properties of the measuring cell, enable fast and reliable signal processing. The measured gas con-centration is transmitted to a Gas Control Panel, which can manage a large number of distributed gas sensors.
Thanks to bus communication, only one cable is required, which can be continued from sensor to sensor. The ME 1250 Gas Sensor is also available with an analogue output signal of 4…20 mA. The measured gas concentration can thereby be processed by other PLC (Programmable Logic Controllers).
The optional relay module expands the ME 1250 Gas Sensor internally with 3 relays for direct switching of signal transmitters without the use of a control panel.
Advantages
- Automatic zero point calibration
- Active noise reduction on the measurement signal
- Linear measurement signal depending on the gas concentration
- High response sensitivity with short response time
- Selective and reliable measurement with a stable measurement signal and zero point
- Temperature-compensated measurement signal
- Long service life
Measuring Ranges
The carbon monoxide sensor can be equipped with two different measuring cells. The exhaust gas variant is suitable for ventilation controls. The more robust industrial variant offers a higher measuring range up to 1,000 ppm. Other measuring ranges on request.
Technical Specifications
Versions
Article codes | ||
---|---|---|
Exhaust gas: 300 ppm Industry: 1,000 ppm | 12BUS-CO-32 12BUS-CO-13 | 1250-CO-32 1250-CO-13 |
Description | Gas Sensor ME 1250 CO Carbon Monoxide Bus communication | Gas Sensor ME 1250 CO Carbon Monoxide Analogue |
Output signal | Bus communication with gas control panel | Analogue 4…20 mA Load max. 800 Ω at 24V input |
Connection | 4-core cable U72M 1x4x0.6 mm Shielded | 3-core cable U72M 1x4x0.6 mm or CY 0.5 mm2 Shielded |
Topology | Bus, tree or star topology | Star topology |
Power | < 0.15 W | < 0.8 W |
Signal Processing
Accessories
Article Code | Description |
1250-REL | Relay module for single sensor ME 1250 |
1250-AIR-BOX | Ventilation duct add-on box for gas sensor ME 1250 |
1250-AIR-FLOW | Fitting hose connection for gas sensor ME 1250 |
1250-SUP | Mounting plate round pillars for gas sensor ME 1250 |
1250-SCHUTZ | Sun and weather protection for gas sensor ME 1250 |
Consumables
Article code | Description | Application | Lifespan |
---|---|---|---|
CELL-CO-M1000 | Measuring cell CO 20 mm | Exhaust gas | up to 3 years |
CELL-CO-CF1000 | Measuring cell CO 32 mm | Industry | up to 3 years |
Gas concentration
- Exposure above measuring range requires recalibration
- High gas concentration can destroy the measuring cell
Cross sensitivity
For the measuring cell CELL-CO-CF1000
Gas | Concentration | Reading |
---|---|---|
Ethene C2H4 | 1,000 ppm | < 250 ppm |
Formaldehyde CH2O | 5 ppm | 0 ppm |
Chlorine Gas Cl2 | 20 ppm | 0 ppm |
Hydrogen H2 | 400 ppm | < 200 ppm |
Hydrogen Sulfide H2S | 20 ppm | 0 ppm |
Hydrogen Chloride HCl | 20 ppm | 0 ppm |
Nitric Oxide NO | 50 ppm | 0 ppm |
Nitrogen Dioxide NO2 | 20 ppm | 0 ppm |
Sulfur Dioxide SO2 | 100 ppm | 0 ppm |
Health hazards
Carbon Monoxide | Symptoms |
---|---|
200 ppm | Slight headache, dizziness |
400 ppm | Headache in the forehead region |
800 ppm | Dizziness and nausea, convulsions within 45 minutes |
1,600 ppm | Unconscious within 2 hours, possible death within 1 hour |
3,200 ppm | Dizziness/nausea for 10 minutes, death within 30 minutes |